By connecting the phases of the U-V-W motor (terminal board or direct wires) with the corresponding U-V-W terminals of the inverter and providing a positive speed command, the motor shaft rotates in accordance with the respective Datasheet.
Once connections have been made, check the following:
Below are instructions for the electrical connection
4a. Cable grommets option- Unscrew and then feed the connecting cables through the cable glands
4b. -Cable Gland Option - Screw on the cable glands to ensure IP sealing.
Below is an overview of the standard cable glands and grommets used.
Follow these directions when verifying the size of the cable used to ensure IP sealing.
| CABLE GLANDS | EXTERNAL WIRING Ø [mm] PLASTIC CABLE GLANDS | EXTERNAL WIRING Ø [mm] NICKEL-PLATED BRASS CABLE GLANDS | | --- | --- | --- | | M12 | 3,5 - 7 | 3 - 6.5 | | M16 | 5 - 10 | 5 - 10 | | M25 | 10 – 17 | 13 - 18 |
CABLE GROMMETS | EXTERNAL WIRING Ø [mm] |
---|---|
M16 | 5 - 9 |
M25 | 11 – 17 |
The thermal sensor, when present, must be connected to a dedicated input of the inverter for proper management of the motor temperature or to a dedicated trip device that can handle any anomalies.
PTY 84-130 sensor resistance characteristics (test current 2 mA)
<aside> <img src="https://prod-files-secure.s3.us-west-2.amazonaws.com/f86d0641-b448-410d-aea9-72e3bcb1af61/5603190e-1cb6-4189-951d-d6a71f0ba138/Immagine_2023-10-05_102801.png" alt="https://prod-files-secure.s3.us-west-2.amazonaws.com/f86d0641-b448-410d-aea9-72e3bcb1af61/5603190e-1cb6-4189-951d-d6a71f0ba138/Immagine_2023-10-05_102801.png" width="40px" /> Manipulation and removal of the component shown in the picture below (THERMAL PROBE CABLE PTY) for any reason, entails an high risk for the integrity and functioning of the motor and of the manipulated/removed component, that would automatically invalidate the product warranty.
</aside>
E-COMER Srl personnel are at your complete disposal if you have any needs in connection with the assembly, use and operation of the motors they produce.
Connection diagrams are provided with the motor depending on the speed sensor solution fitted. Contact e-comer Srl. technical department for more information than what is in the engine packaging.
<aside> <img src="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/0a62e976-f3af-46b3-a494-6f4ab42d0de8/general-warning-sign_hires.png" alt="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/0a62e976-f3af-46b3-a494-6f4ab42d0de8/general-warning-sign_hires.png" width="40px" /> The phasing, for proper operation of Encoder RM44, is fine-tuned and fixed by Screws. The latter are marked with safety paint and CAN NOT be tampered with prior authorization from e-comer Srl.
</aside>
<aside> <img src="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/01f1c028-54d1-49d2-ac66-509f56a2b0b8/general-warning-sign_hires.png" alt="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/01f1c028-54d1-49d2-ac66-509f56a2b0b8/general-warning-sign_hires.png" width="40px" /> Per ulteriori consultare il manuale SMAC al seguente link: